Servicing all of Greater Hickory Area

SPEC SHEET

Hormann-Flexon Speed Commander™ 1400 Sel Food Master

STAINLESS OPTIONS MEET ALL REQUIREMENTS

The Food-Master design allows you to select only the stainless steel options your application requires. Able to conform with all industry requirements, the following components are available in stainless steel, making it possible to conveniently build a Food-Master door without paying for unnecessary stainless options: Roll tube / shaft, door / motor cover, guide tracks and all hardware.

CHOICE OF TWO FOOD-GRADE PANEL MATERIALS

Two effective panel materials are available on the Food-Master. The standard is a 40 oz. / sq. yard white nylon-reinforced, puncture resistant PVC, perfect for basic applications. An optional 90 oz. / sq. yard 100 percent FDA approved white polyurethane panel material is available when optimum compliance is needed. A vision area is unavailable with the 90 oz. material to maintain FDA acceptance. With either material, the panel maintains stability via spring steel stiffeners located in completely sealed panel pockets.

BUILT-IN LIGHT GRID EFFECTIVE AFTER WASH-DOWN

Standard on the Food-Master is a light grid built into the guide tracks up to 8’0″ high. Completely free of coil cords, the light grid provides a thorough wall of protection for personnel and equipment in the doorway, as compared to other doors that use only photocells. The light grid also eliminates the need for a panel reversing edge, which is typically vulnerable to damage, resulting in a reduction in maintenance and downtime. Amazingly, the light grid remains an effective protection device even following wash-down.

Application / Size Range

Application / Size

Interior applications up to 14’0″ wide x 16’0″ high.
Panel

Select only the stainless steel components required.
Choose from: Roll tube/shaft, door/motor cover, guide tracks and all hardware.
Standard panel material: 40 oz. / sq. yard white nylon-reinforced PVC.
Optional panel material: 90 oz. / sq. yard 100 percent FDA approved white polyurethane.

Vision

Optional: Full-width x 35″ high, clear PVC, starting at approximately 52″ from the floor and is only available with the 40 oz. / sq. yard white PVC.
Colors

Pure White
Operating Speed

Opening: Up to 80″ per second.
Closing: 30″ per second.
Guide Tracks

Standard: Galvanized steel.
Optional: Stainless steel.

Direct-Drive Motor

Standard: Compact, self-monitoring direct-drive motor has a patented built-in catch system and is maintenance free.
Optional: NEMA 4x including hollow shaft in stainless steel.
Control Box

Standard: HFCB 1-phase hardwired. Optional UPS emergency battery pack
Optional: HFC1 hardwired 3-phase™ or Unique Smart Start HFC1.
Safety Devices

Standard: Light grid built into guide tracks up to 8’0″ high.

Hormann-Flexon Speed Master® 4600

BULLDOG-TOUGH PANEL

Recommended for exterior or interior door openings up to 33’0″ wide x 30’0″ high or 690 square feet, the Speed-Master® 4600 is constructed of patented, interlocking aluminum hinges which act as integral windbars, creating a sectional panel design that provides panel stability and increased wind resistance. Sliding the panels apart without removing the entire door or roll assembly allows for inexpensive replacement, and a full-width vision area provides unobstructed viewing. Since the Speed-Master® bottom bar consists of few parts, does not support a tensioning system, and requires less repair time, it can be replaced at a lower cost than comparable products.

UNIQUE ENERGY CHAIN

The Model 4600 has low profile heavy duty steel guide tracks that contain a sophisticated energy chain which allows for automatic reversal of the panel and eliminates the use of a coil cord, for a streamline installation. Full perimeter draft seals provide dust and odor containment as well as general environmental control.

SPECIAL 5 & 2 WARRANTY

Demanding industries such as manufacturing, mass transit, warehouses and waste management facilities will benefit from the simple and reliable design of the Speed-Master® 4600. Design advantages such as zero moving parts within the guide tracks and direct-drive motor, support minimized maintenance for the walk-away dependability busy operations desire.

Our exclusive 5 & 2 Warranty is our promise to you that you can count on our doors to perform according to your standards for many years to come.

Application / Size Range

Application / Size

Exterior or Interior applications.
Up to 33’0″ wide x 30’0″ high or 690 sq. ft.
Operating Speed

Up to 24″ per second up and 24″ per second down.
Panel

Patented, sectional panel design, made of ultra tough, reinforced, puncture resistant 1/8″ thick Bulldog XT material, 90 oz. / sq. yd. Panels are connected with heavy duty aluminum hinge profiles.

Vision

Two, full-width vision areas made of high quality PVC are standard. Consult factory for additional vision areas.

Direct-Drive Motor

Compact, self-monitoring direct-drive motor has a patented built-in catch system and is maintenance free.

Control Box

Standard: Hardwired with 230 or 460 v / 3-phase / 60 Hz power requirement.

Safety Devices

Standard: Lightweight energy chain.

Custom Panel Prints

Make an impression with our customized panel prints! Logos, pictures and text may be digitally printed onto our door panels. The images are durable, UV treated and waterproof. The maximum image size is 7’0″ wide x 3’0″ high.

Colors

Black
Blue
Orange
Grey
Guide Tracks
Hinged, heavy-duty steel.

SPEC SHEET

Hormann-Flexon Speed-Commander™ 1200 Dock-Master Screen-Master®

HIGH SPEED DOOR WITH SIMPLE DESIGN FOR NO-FRILLS APPLICATIONS

The Speed-Commander™ 1200 Dock-Master / Screen-Master® is a heavy duty high speed door intended for low-frequency use. Designed to be raised or lowered with a constant pressure push button at a speed of 14″ per second, it is perfect for door openings where overhead garage doors are installed. The basic non-timer control box has a 110 v / 1 phase / 60 Hz power requirement. Standard operation is hold to open / hold to close, and when automatic closing is required, an optional built-in light grid is included.

LIGHT GRID AVAILABLE FOR ADDED PROTECTION

Basic operation is hold to open / hold to close, and when automatic closing is required, an optional built-in light grid is included. Completely free of coil cords, the light grid provides a thorough wall of protection for personnel and equipment in the doorway, as compared to other doors that use only photocells. The light grid also eliminates the need for a panel reversing edge, which is typically vulnerable to damage, resulting in a reduction in maintenance and downtime. Full perimeter draft seals reinforce general environmental control.

OPTIONAL SCREEN PANELS FOR VENTILATION

The Dock-Master / Screen-Master® comes in a sectional panel design. The panels are connected using aluminum profiles which allows for fast panel replacement when required. Our high-strength, polyester screen material can be interchanged with the solid panels in order to provide ventilation during the warmer months. This panel can be easily interchanged without special tools and is the solution to help prevent airborne contaminents such as birds and insects from entering the building.

Application / Size Range

Application / Size

Interior applications up to 14’0″ wide x 14’0″ high.
Exterior applications up to 10’0″ wide x 10’0″ high.
With insect screen material up to 14’0″ wide x 14’0″ high.
Panel

Interior door openings: 58 oz. / sq. yard reinforced PVC.
Exterior door openings: High-impact, tear-resistant material.
Vision

Optional: Full-width x 35″ high, clear PVC, starting at approximately 52″ from the floor.

Colors

Zinc Yellow (RAL 1018) (Interior applications)
Pure Orange (RAL 2004) (Interior applications)
Carmine Red (RAL 3002) (Interior applications)
Gentian Blue (RAL 5010) (Interior applications)
Agate Grey (RAL 7038) (Interior applications)
Black (Exterior applications)
Blue (Exterior applications)
Operating Speed

Opening: 14″ per second.
Closing: 14″ per second.

Guide Tracks

Galvanized steel.

Direct-Drive Motor

Standard: Compact, self-monitoring direct-drive motor has a patented built-in catch system and is maintenance free.
Control Box

Standard: Basic non-timer, 110 v / 1 phase / 60 Hz.
Optional: Automatic closing.
Safety Devices

Optional: Light grid built into guide tracks up to 8’0″ high.

Hormann-Flexon Speed-Commander™ 1400 Sel Cool-Master

FOAM PANEL MATERIAL FOR OPTIMUM ENERGY SAVINGS
This is the ideal door for energy conscious, 24/7/365 applications in agricultural, medical and cooler distribution facilities. The fast operating speeds allow for a constant flow of traffic without compromising energy control and efficiency. An advanced 3 mm thick gray foam panel material maintains flexibility to +33 degrees F and helps to keep condensation to a minimum in cooler to ambient areas. Our unique sectional panel design makes it possible to replace panels easily for minimal downtime.

SINGLE PHASE CONNECTION / 3-PHASE DRIVE
The Cool-Master accommodates the standard power sources readily available in most facilities with the HFCB control box which is hardwired and standard with a 230 v / 1-phase / 60 Hz / 3-phase output requirement. An optional UPS emergency battery pack is available with doors that are equipped with our 230 v / 1-phase HFCB control box. Optional are both the HFC1 3-phase, hardwired control box and the proven and tested Smart Start™ HFC1 3-phase control box, when UL approval and ultimate operational speed is required.

BUILT-IN LIGHT GRID FOR ADDED PROTECTION
Standard on the Cool-Master is a light grid built into the guide tracks up to 8’0″ high. Completely free of coil cords, the light grid provides a thorough wall of protection for personnel and equipment in the doorway, as compared to other doors that use only photocells. The light grid also eliminates the need for a panel reversing edge, which is typically vulnerable to damage, resulting in a reduction in maintenance and downtime. Full perimeter draft seals provide additional environmental control.

BROCHURE

Application / Size Range

Application / Size

  • Interior applications up to 14’0″ wide x 16’0″ high.

Panel

  • 3 mm thick foam fabric connected with heavy duty aluminum profiles

Vision

  • Optional: Full-width x 35″ high, clear PVC, starting at approximately 52″ from the floor.

Colors

  • Gray

Operating Speed

  • Opening: Up to 80″ per second.
  • Closing: 30″ per second.

Guide Tracks

  • Standard: Galvanized steel.
  • Optional: Stainless steel.

Direct-Drive Motor

  • Standard: Compact, self-monitoring direct-drive motor has a patented built-in catch system and is maintenance free.

Control Box

  • Standard: HFCB 1-phase, hardwired. The optional UPS emergency battery pack is only available with doors that are equipped with our 230 v / 1-phase HFCB control box.
  • Optional: HFC1 3-phase, hardwired or Smart Start™ HFC1 3-phase.

Safety Devices

  • Standard: Light grid built into guide tracks up to 8’0″ high.

Hormann-Flexon Speed-Commander™ 1400 Sel Interior Door

BUILT-IN LIGHT GRID
Standard on the Speed-Commander™ 1400 SEL is a light grid built into the guide tracks up to 8’0″ high. Completely free of coil cords, the light grid provides a thorough wall of protection for personnel and equipment at the doorway, as compared to other doors that use only photocells. Full perimeter draft seals provide dust and odor containment, as well as general environmental control.

SINGLE PHASE CONNECTION / 3-PHASE DRIVE
The enhanced Speed-Commander™ 1400 SEL now accommodates the standard power sources readily available in most facilities. The HFCB control box is hardwired and standard with 230 v / 1 phase / 3 phase output power, for an opening speed up to 80″ per second. When UL / CUL approval is required, the HFC1 3 phase, hard-wired or Smart Start™ HFC1 3 phase control boxes are options.

Optional UPS Emergency Battery Pack – Available with doors equipped with our 230 v / 1-phase HFCB control box. With this option, if power is lost to the door, the UPS emergency battery pack automatically opens the door once to allow personnel to quickly exit the area.

SECTIONAL PANEL DESIGN
The Speed-Commander™ 1400 SEL now comes in a sectional panel design. The panels are connected using aluminum profiles and have specially designed edges that allow the panels to slide easily into the horizontal aluminum profiles for fast replacement.

Application/Size Range

Application / Size

  • Interior applications up to 14’0″ wide x 16’0″ high.

Operating Speed

  • Opening: Up to 80″ per second.
  • Closing: 30″ per second.

Panel

  • Anti-static, puncture resistant, nylon-reinforced PVC material.
  • Weight: 58 oz. / sq. yd.
  • Tear strength: 440 lbs. / sq. ft.
  • Temperature rating: -22°F to +158°F.

Vision

Full-width x 35″ high, clear PVC, starting at approximately 52″ from the floor. The panels are connected using aluminum profiles and have specially designed edges that allow the panels to slide easily into the horizontal aluminum profiles for fast replacement.

Colors

  • Zinc Yellow (RAL 1018)
  • Pure Orange (RAL 2004)
  • Carmine Red (RAL 3002)
  • Gentian Blue (RAL 5010)
  • Agate Grey (RAL 7038)

Guide Tracks

  • Standard: Heavy-duty, 12 gauge, galvanized steel with removable front covers. Guide tracks are 7-1/4″ wide x 4-1/2″ deep with up to an 8’0″ high light grid built in.
  • Optional: Stainless steel.

Direct-Drive Motor

  • Compact, self-monitoring direct-drive motor has a patented built-in safety brake and is maintenance free.

Control Box

  • Standard: HFCB 1-phase, hardwired.
  • Optional: HFC1 3-phase, hardwired or Smart Start™ HFC1 3-phase.

Safety Devices

  • Standard: SoftEdge bottom profile with integral wireless panel reversing edge.
  • Up to an 8’0″ high light grid built into the guide tracks.

Custom Panel Prints

Make an impression with our customized panel prints! Logos, pictures and text may be digitally printed onto our door panels. The images are durable, UV treated and waterproof. The maximum image size is 7’0″ wide x 3’0″ high.

Hormann-Flexon Speed-Guardian™ 4000 U

URETHANE PANEL SECTIONS
The 1-5/8″ thick door panel made of hot-dipped galvanized steel, provides a durable and lasting surface. A urethane core with an R-value of 13.6 and U-value < 0.5 (U-value of core and steel skin) provides optimum insulation, reduces loss of conditioned air and contributes to energy savings. Synthetic panel connectors provide an extremely smooth and quiet door operation.

BUILT-IN LIGHT GRID
The standard light grid is integral with the guide tracks making it less susceptible to damage by passing loads. This system enhances protection of personnel and goods and drastically reduces the likelihood of damage and repair to other parts of the door, saving on maintenance costs.

EXCLUSIVE DURATEC® INSULATED WINDOWS
The Duratec®insulated windows are coated with a special finish which prevents marks and scratches caused by cleaning, and retain clear view after many cleanings. The synthetic double panes provide good thermal insulation while being fully transparent. The Speed-Guardian™ 4000 U door is available with a complete vision panel, designed for the pleasing aesthetic appeal some applications require.

VIDEO
Application / Size Range

Application / Size

  • Suitable for exterior or interior applications up to 22’0″ wide x 20’0″ high.
  • Full-view option available for doorways up to 16’0″ wide x 16’0″ high.

Operating Speed

  • Opening: Up to 80″ per second.
  • Closing: 18″ per second.

Panel

  • 1-5/8″ thick x 10″ high panel sections are made of hot-dipped galvanized steel with a urethane foam core and have an R-value of 13.6. Section joints with intermediate seals create a pinch resistant panel.
  • The standard color is RAL 9006 White Aluminum on both the exterior and interior. The exterior surface comes with a Micrograin™ finish, the interior is stucco-textured.

Comparing R-value and U-value

R-value refers only to the panel’s resistance against energy loss. U-value is an internationally recognized measurement tool that provides data about the energy flow lost through the total panel construction including the panel, seals, windows, etc. The 4000’s solid sections provide the most efficient U-value available today.

Vision

  • Optional windows are 7″ high acrylic, doublepane, with vertical reinforcement and black window frames.
  • A Duratec® synthetic glazing enables the windows to retain clear view even after many cleanings and with heavy use. The optional complete vision panel has windows running the entire height of the door.

Guide Tracks

  • Guide tracks are made of hot-dipped galvanized steel and have an enclosed chain and integral light grid.
  • The chain requires no re-tensioning and is resistant to distension.
  • Optional low-headroom track configuration available. Consult factory for more information.

Direct-Drive Motor

  • Compact, self-monitoring direct-drive motor has a patented built-in catch system and is maintenance free.

Control Box

  • Unique Smart Start™ HFC1.

Safety Devices Standard

  • 8’0″ high light grid integral with the guide tracks.
  • Emergency opening via hand chain hoist and spring counterbalance.
BROCHURE

Hormann-Flexon Speed-Master 1600 L Eco

BUILT-IN LIGHT GRID AND REMOVABLE COVERS
The Speed-Master® 1600 L Eco is equipped with heavy duty 12 gauge hot-dipped galvanized steel guide tracks and a standard built in light grid. The front covers conveniently open for ease in re-setting the door when required. Completely free of coil cords, the light grid provides a thorough wall of protection for personnel and equipment at the doorway, as compared to other doors that use only photocells. The low-profile track dimensions of 7-1/4″ wide x 4-1/2″ projection enable the Eco to fit into areas with limited clearance.

SECTIONAL DESIGN WITH 58 OZ. PANEL MATERIAL
The Eco’s panel is constructed of 58 oz./sq. yd., anti-static, puncture resistant, nylon-reinforced PVC material, one full-width vision area made of clear PVC is standard, and heavy duty interlocking aluminum hinge profiles located above and below the vision area to provide panel stability. The sectional panel design allows for easy replacement of materials if needed after a hit. A variety of panel colors are available to accommodate any color scheme: Pure Orange RAL 2004, Gentian Blue RAL 5010, Zinc Yellow RAL 1018, Carmine Red RAL 3002, Agate Gray RAL 7038, Pure White RAL 9010.

OPTIONAL UPS EMERGENCY BATTERY PACK
The Speed-Master® 1600 L Eco is only available with the HFCB 1-phase control box. A special UPS emergency battery pack is optional and provides peace-of-mind in case of a power failure. If power is lost to the door, the UPS emergency battery pack automatically opens the door once to allow personnel to quickly exit the area. This low maintenance design is free of springs, counterbalance systems and other high maintenance parts that are typically required for emergency opening. When the battery is low, an alarm sounds to signal time for replacement. Replacing the battery is a simple process that takes just a few minutes.

Application / Size Range

Colors

  • Orange
  • Blue
  • Yellow
  • Red
  • Gray
  • White

Guide Tracks

  • Standard: Heavy-duty, 12 gauge, galvanized steel with removable front covers. Guide tracks are 7-1/4″ wide x 4-1/2″ deep with an 8’0″ high light grid built in.
  • Optional: Stainless steel.

Direct-Drive Motor

  • Compact, self-monitoring direct-drive motor has a patented built-in safety brake and is maintenance free.

Application / Size Range

  • Interior or exterior applications.
  • Up to 12’0″ wide x 12’0″ high.

Operating Speed

  • Up to 60″ per second up and 30″ per second down.

Panel

  • Patented, sectional design constructed of 58 oz./sq. yd., reinforced, puncture resistant PVC panels connected with heavy duty aluminum hinge profiles.

Vision

  • Full-width vision area made of high quality PVC is standard. Consult factory for additional vision areas.

Control Box

  • Standard: HFCB 1-phase, hardwired. 230 v / 1-phase / 60 Hz / 3-phase output power requirement.

Safety Devices

  • Standard: 8’0″ high light grid built into guide tracks.

Custom Panel Prints

  • Make an impression with our customized panel prints! Logos, pictures and text may be digitally printed onto our door panels. The images are durable, UV treated and waterproof. The maximum image size is 7’0″ wide x 3’0″ high.

Hormann-Flexon Speed-Master® 1600 L

BUILT-IN LIGHT GRID
Standard on the Speed-Master® 1600 L is a light grid built into the guide tracks up to 8’0″ high. Completely free of coil cords, the light grid provides a thorough wall of protection for personnel and equipment at the doorway, as compared to other doors that use only photocells. Full perimeter draft seals provide dust and odor containment, as well as general environmental control.

GUIDE TRACKS WITH REMOVABLE COVERS
The Speed-Master® 1600 L has guide tracks with removable covers. Heavy duty 12 gauge hot-dipped galvanized steel tracks are a two-piece design, and the front covers conveniently open for ease in re-setting the door when required. The low-profile tracks dimensions of 7-1/4″ wide x 4-1/2″ projection enable the Speed-Master® 1600 L to fit into areas with limited clearances.

SINGLE PHASE CONNECTION / 3-PHASE DRIVE
The enhanced Speed-Master® 1600 L now accommodates the standard power sources readily available in most facilities. For doors up to 10’0″ wide x 10’0″ high, the HFCB control box is hardwired and standard with a 230 v / 1-phase / 60 Hz / 3-phase output power requirement. For doors over 10’0″ wide x 10’0″ high, the 230 v or 460 v / 3-phase / 60 Hz UL listed control box is standard. Optional for all sizes are both the HFC1 3-phase, hardwired control box and the proven and tested Smart Start™ HFC1 3-phase control box when UL approval is required.

OPTIONAL UPS EMERGENCY BATTERY PACK
Available with doors equipped with our 230 v / 1-phase HFCB control box. With this option, if power is lost to the door, the UPS emergency battery pack automatically opens the door once to allow personnel to quickly exit the area.

Application / Size Range

Application / Size

  • Range Exterior or Interior applications.
  • Up to 14’0″ wide x 16’0″ high.

Operating Speed

  • Up to 60″ per second up and 30″ per second down.

Panel

  • Patented, sectional panel design, made of ultra tough, reinforced, puncture resistant 1/8″ thick Bulldog XT material, 90 oz. / sq. yd. Panels are connected with heavy duty aluminum hinge profiles.

Vision

  • Two, full-width vision areas made of high quality PVC are standard. Consult factory for additional vision areas.

Colors

  • Black
  • Blue
  • Orange
  • Grey

Guide Tracks

  • Standard: Heavy-duty, 12 gauge, galvanized steel with removable front covers. Guide tracks are 7-1/4″ wide x 4-1/2″ deep with an 8’0″ high light grid built in.
  • Optional: Stainless steel (see Food Processing Compliant Model).

Direct-Drive Motor

  • Compact, self-monitoring direct-drive motor has a patented built-in safety brake and is maintenance free.

Control Box

  • Standard: For doors up to 10’0″ wide x 10’0″ high, HFCB 1-phase, hardwired.
  • For doors over 10’0″ wide x 10’0″ high, 230 v or 460 v / 3-phase / 60 Hz UL listed control box.

Optional for all sizes

  • HFC1 3-phase, hardwired or Smart Start™ HFC1 3-phase.
  • HFC1 3-phase, hardwired stainless steel (see Food Processing Compliant Model).

Safety Devices

Standard: 8’0″ high light grid built into guide tracks.

Food Processing Compliant Model

Stainless steel options are available. Select from the following depending on the application requirements: Roll-tube / hollow shaft, motor cover, guide tracks, stainless steel HFC1 3-phase hardwired control box. Panel constructed of 1/8″ thick, 90 oz. / sq. yd. USDA compliant Bulldog XT material and two full-width vision areas made of high quality USDA compliant PVC.

Custom Panel Prints

Make an impression with our customized panel prints! Logos, pictures and text may be digitally printed onto our door panels. The images are durable, UV treated and waterproof. The maximum image size is 7’0″ wide x 3’0″ high.

BROCHURE

Hormann-Flexon Speed-Master® 2600 L

BUILT-IN LIGHT GRID AND HINGED GUIDE TRACKS
Standard on the Speed-Master® 2600 L is a light grid built into the guide tracks up to 8’0″ high. Completely free of coil cords, the light grid provides a thorough wall of protection for personnel and equipment in the doorway, as compared to other doors that use only photocells. The light grid also eliminates the need for a panel reversing edge, which is typically vulnerable to damage, resulting in a reduction in maintenance and downtime. Full perimeter draft seals provide dust and odor containment as well as general environmental control.

IDEAL FOR DEMANDING APPLICATIONS
Demanding industries such as manufacturing, paper mills, steel plants, airports, distribution and transit, that have high cycle door requirements, will benefit from the simple and reliable design of the Speed-Master® 2600 L. Design advantages such as zero moving parts within the guide tracks and direct-drive motor, support minimized maintenance for the walk-away dependability busy operations desire.

Our exclusive 5 & 2 Warranty is our promise to you that you can count on our doors to perform according to your standards for many years to come.

TWO CONTROL BOX CHOICES
A hardwired UL / CUL control box with a 230 or 460 v / 3-phase / 60 Hz power requirement is standard equipment on the 2600 L. Optional is our proven and tested Smart Start™ HFC1 3-phase plug and play control box with is also UL / CUL approved.

Application/Size Range

Application / Size

  • Exterior or Interior applications.
  • Up to 20’0″ wide x 24’0″ high.

Operating Speed

  • Up to 36″ per second up and 30″ per second down.

Panel

  • Patented, sectional panel design, made of ultra tough, reinforced, puncture resistant 1/8″ thick Bulldog XT material, 90 oz. / sq. yd. Panels are connected with heavy duty aluminum hinge profiles.

Colors

  • Black
  • Blue
  • Orange
  • Grey

Vision

  • Two, full-width vision areas made of high quality PVC are standard. Consult factory for additional vision areas.

Guide Tracks

  • Heavy-duty galvanized steel.

Direct-Drive Motor

  • Compact, self-monitoring direct-drive motor has a patented built-in catch system and is maintenance free.

Control Box

  • Standard: Hardwired UL / CUL with 230 or 460 v / 3-phase / 60 Hz power requirement.
  • Optional: Unique Smart Start™ HFC1.

Safety Devices

Standard: 8’0″ high light grid built into the guide tracks.

Custom Panel Prints

Make an impression with our custom panel prints! Logos, pictures and text may be digitally printed onto our door panels. The images are durable, UV treated and waterproof. The maximum image size is 7’0″ wide x 3’0″ high.

Hormann-Flexon Ups Emergency Battery Pack

Peace-of-mind with Optional UPS Emergency Battery Pack

Offered as an option on the Speed-Commander™ 1400 SEL, Clean-Master, Cool-Master, Food-Master and Speed-Master 1600 L doors, our completely unique UPS emergency battery pack provides peace-of-mind in case of a power failure. If power is lost to the door, the UPS emergency battery pack automatically opens the door once to allow personnel to quickly exit the area. This low maintenance option is free of springs, counterbalance systems and other high maintenance parts that are typically required for emergency opening. When the battery is low, an alarm sounds to signal time for a replacement. Replacing the battery is a simple process that takes just a few minutes.